MINIATURE CUBE SOLID STATE, DC VOLTAGE

TBC Miniature Timers

Solid State DC Voltage

Timing Mode | Delay on Make

Category | Solid State Timer

Series | TBC

TBC timers are solid state output units with digital timing and come in a 1⅝" square case.

Ease of installation and hook-up is a primary design benefit. All models are available with integral time adjustment knob or factory-fixed time, and require only three connections.

Timing Mode

Application of input voltage to the timer starts the time delay. At the end of the delay period, the load is energized. To reset, remove the input voltage to the timer.

Solid State DC Voltage
  • Digital timing, solid state MOSFET output
  • 1 Amp current load handling
  • 10 Amps 100 ms (millisecond) surge handling
  • Higher current available
  • Wide DC voltage range
  • ±0.1% Repeat accuracy
  • Virtually unlimited time ranges
  • Factory-fixed or variable timing adjustment
  • Totally encapsulated for protection from harsh environments
  • O-ring sealed exposed controls
  • Single screw mounting through center mounting hole
  • Standard 6.35mm (0.25") quick connect blade terminals
  • 100% Operational testing before shipping
  • RoHS compliance available
Solid State DC Voltage
  • Repeat Accuracy
    ±0.1% under fixed conditions
  • Timing Ranges
    0.05 sec. to 24 hours (1 sec., 10 sec., 100 sec., and 1000 secs. are standard)
    Special time ranges available upon request
  • Reset/Recycle Time
    100 milliseconds
  • Tolerances
    Fixed: ±10% of nominal time
    (optional: ±5%, ±1%)
    Variable: -0%, +15%
    Limit: -10% at minimum time
  • Recycle Effect
    None
  • Temperature Ranges
    Storage: -40°C to +85°C
    Operating: -25°C to +65°C
  • Life Expectancy
    No predictable failure if used within operating parameters
  • Protection
    Polarity Protection: All DC units have reverse polarity protection
    Transient Protection: 18 joules
    Dielectric Strength: 1800V RMS 60Hz
  • Power Requirement
    0.25 watts max
  • Weight
    3oz. (85g) maximum
  • Solid State Output
    SPST (N.O.)
  • Load Current
    1 amp continuous, 10 amps 100 ms surge
    Higher current available
  • Time Cycle Interrupt (Input Voltage Break)
    Resets timer to original state