Power is continuously applied to the input terminals of the timer. Upon closure of a Normally Open (N.O.) external initiate switch, the load transfers immediately and remains transferred as long as the external initiate switch is closed. Commencement of the time delay is deferred by maintaining closure of the external initiate switch. Opening the initiate switch starts the time delay. At the end of the delay period, the load de-energizes and the timer is ready for another cycle. Delay time may be reset to beginning, prior to the end of the delay period, by momentarily reclosing (pulsing) the initiate switch.
        
                
                
                
                
                    TGM
                    Delay on Break Relay Timer
                    
                      
                        
                        
                            - Compact 2" x 2" configuration
 
                            - Relay outputs from 10 to 30 amps
 
                            - Cost-effective alternative to plug-in relay
 
                            - Factory-fixed or variable timing
 
                        
                         
                     
                    
                 
                
                
                
                    TGMB
                    Delay on Break Relay Timer
                    
                        
                        
                        
                            - Compact 2" x 2" configuration
 
                            - Relay outputs from 10 to 20 amps
 
                            - Dry initiate switch and isolated contact
 
                            - Factory-fixed or variable timing
 
                        
                         
                     
                    
                 
                
                
                
                    TGML
                    Delay on Break Relay Timer
                    
                        
                        
                        
                            - Compact 2" x 2" configuration
 
                            - Relay outputs from 10 to 30 amps
 
                            - Hot initiate switch and non-isolated contact
 
                            - Factory-fixed or variable timing
 
                        
                         
                     
                    
                 
                
                
                
                
                                
                
                
                    TGMLB
                    Delay on Break Relay Timer
                    
                        
                        
                        
							- Compact 2" x 2" configuration
 
							- Relay outputs from 10 to 20 amps
 
							- Hot initiate switch and non-isolated contact
 
							- Factory-fixed or variable timing
 
                        
                         
                     
                    
                 
                
                
                
                    TGMV
                    Delay on Break Relay Timer Voltage Control
                    
                        
                        
                        
                            - Compact 2" x 2" configuration
 
                            - 10 amp relay output
 
                            - Voltage control switch
 
                            - Factory-fixed or variable timing
 
                        
 
                     
                    
                 
                
                
                
                    TGMVB
                    Delay on Break Relay Timer Voltage Control
                    
                        
                        
                        
                            - Compact 2" x 2" configuration
 
                            - 10 amp relay output
 
                            - Voltage control switch with non-isolated contact
 
                            - Factory-fixed or variable timing
 
                        
                         
                     
                    
                 
                
                
                
                
                
                
                
                    TH3M
                    Delay on Break Solid State Timer
                    
                        
                        
                        
                            - Compact 2" x 2" configuration
 
                            - Solid state 1 amp output
 
                            - Dry initiate switch
 
                            - Factory-fixed or variable timing
 
                        
 
                     
                    
                 
                
                
                
                    TH3ML
                    Delay on Break Solid State Timer
                    
                        
                        
                        
                            - Compact 2" x 2" configuration
 
                            - Solid state 1 amp output
 
                            - Hot initiate switch
 
                            - Factory-fixed or variable timing
 
                        
 
                     
                    
                 
                
                
                
                    TNM
                    Delay on Break Plug-In Relay Timer
                    
                        
                        
                        
                            - 8-pin or 11-pin Plug-in timer
 
                            - Easy install; excellent field replacement timer
 
                            - Sealed relays
 
                            - Factory-fixed or variable timing
 
                        
 
                     
                    
                 
                
                
                
                
                
                
                
                    TNML
                    Delay on Break Plug-In Relay Timer
                    
                        
                        
                        
                            - 8-pin or 11-pin Plug-in timer
 
                            - Easy install; excellent field replacement timer
 
                            - Hot initiate switch
 
                            - Factory-fixed or variable timing
 
                        
 
                     
                    
                 
                
                
                
                    TH3XM
                    Delay on Break Solid State Timer, High Power
                    
                        
                        
                        
                            - Digital timing, solid state output
 
                            - 10 Amp continuous current handling
 
                            - 60 Amp AC single-cycle surge handling
 
                            - Factory fixed, variable or external timing adjustment
 
                        
                         
                     
                    
                 
                
                
                
                    TH3XML
                    Delay on Break Solid State Timer, High Power
                    
                        
                        
                        
                            - Digital timing, solid state output
 
                            - 10 Amp continuous current handling
 
                            - 60 Amp AC single-cycle surge handling
 
                            - Factory fixed, variable or external timing adjustment